Low-E™ House-wrap. This revolutionary new product is just what builders
have been looking for. A house wrap that does more than simply stop drafts.
A pure aluminum facing is heat bonded to one or both sides of closed cell polyethylene
foam, then the product is pin perforated. This results in a house-wrap that
acts not only as a superior air infiltration barrier, effectively sealing up
cracks or gaps in the external sheathing, but it also adds an insulation to
the exterior of the home blocking up to 97% of radiant heat. This results in
better year round efficiency and comfort levels. Also unlike other house-wraps
or insulating products that are traditionally used, Low-E™ House-Wrap
is totally non-toxic, and its performance is not affected by initial exposure
to the elements. This product is a special order item in 4' x 125' rolls that weigh only
about 20lbs, 5’. Installation
is a breeze, using only a staple gun and razor knife.
Benefits of Low-E Housewrap:
- Adds radiant barrier to outside of home
- Non-toxic, no fiberglass - no itching
- Reduces Drafts
- Installs easily with razor knife and foil tape
- Class A Class 1 Fire Rating
- Superior thermal performance
- Flexible and durable
- Improves insulation systems performance
- Insect / Bird Resistant
- Great for new construction or retrofits This product
Finished Dimension:
48” x 125’ Shipped in roll form.
60” x 100’ (Special Order) Shipped in roll form.
1/8” (Special Order) Shipped in roll form.
Core Material:
Polyethylene
Facing:
99.4% Polished Aluminum non reinforced one side
Perm Rating:
ASTM E-96:4.65 or 34.3 Grams(day-m2) (based on single sided house-wrap)
Flame and Smoke:
ASTM E-84-97a Flame Spread: 0 Smoke Developed:14
R-Value:
R-4*
*System R-Values calculated by GEOSCIENCE LTD. Report available upon request.
†R-Values may vary depending on facing assembly
DO NOT install with foam exposed. DO NOT leave this product exposed on walls
or ceilings where ceilings are under 10’. Areas
under 10’ should be covered with a proper thermal barrier. See your local
Code Official for more information.
Warning: Although ESP Low-E® Insulation Products are all
ASTM ?re tested and have excellent ?re ratings; it is recommended
that they or any insulation material should not be exposed to open frame or
other ignition sources of sufficient intensity during shipment, storage or installation.
Caution: Aluminum is an Electrical Conductor. Please use caution
when working around electrical sources including overhead power lines.
For the most up-to-date/most economical shipping rates please call Radiant Barrier Solutions at: 704.824.1171
|